Technical Specifications of NSN
Overall Length:
3.160 inches
Body Length:
2.630 inches
Body Height:
1.870 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
2.125 inches
Vibration Resistance Range In Hertz:
+10.0/+55.0
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
0.562 inches
Operating Tempurature Range:
-55.0/+65.0 degrees celsius
Operating Tempurature Range:
-55.0 to 65.0 degrees celsius
Average Life Rating In Hours:
10000.0
Reference Frequency Per Function:
50.0 7th high pass any acceptable
Reference Frequency Per Function:
1.276 single radio interference any acceptable
Reference Frequency Per Function:
50.0 hertz single low pass 2nd function
Source Impedance Rating Per Function:
1.2 kilohms single band pass
Source Impedance Rating Per Function:
1.2 kilohms single low pass
Source Impedance Rating Per Function:
1.2 kilohms single low pass 2nd function
Input Impedance Per Function W/load:
50.0 ohms blank
Output Impedance Per Function W/source Across Input:
2.4 kilohms single band pass
Output Impedance Per Function W/source Across Input:
2.4 kilohms single low pass
Output Impedance Per Function W/source Across Input:
2.4 kilohms single band pass 1st function
Principal Circuitry Type Per Function:
Inductance-capacitance single low pass
Principal Circuitry Type Per Function:
Inductance-capacitance-resistance single band pass
Principal Circuitry Type Per Function:
Inductance-capacitance single low pass 2nd function
Mounting Facility Screw Thread Series Designator:
Unc
Mounting Facility Type And Quantity:
2 threaded hole
Insertion Loss At Reference Frequency Per Function In Decibels:
3.0 single low pass
Insertion Loss At Reference Frequency Per Function In Decibels:
6.0 single band pass
Functional Terminal Type And Quantity:
1 standard tube base output 2nd function
Functional Terminal Type And Quantity:
1 wire hook ground 3rd function
Functional Terminal Type And Quantity:
2 wire hook input 1st function
Specified Frequencies Of Discrimination Per Function:
1.00 hertz single low pass and 100.00 hertz single low pass and 2.00 kilohertz single low pass and 4.00 kilohertz single low pass
Thread Size:
0.138 inches
Frequency Band Width Per Function:
1.00 hertz single low pass and 100.00 hertz single low pass
Frequency Band Width Per Function:
1.236 kilohertz single band pass and 1.316 kilohertz single band pass
Frequency Band Width Per Function:
1.00 hertz single low pass and 100.00 hertz single low pass
Frequency Band Width Per Function:
1.236 kilohertz single band pass and 1.316 kilohertz single band pass 1st function
Discrimination At Specificationified Frequencies Per Function In Decibels:
3.0 blank and 3.0 blank and 50.0 blank and 50.0 blank
Style Designator:
Rectangular terminal/terminals on opposite surfaces
Item Name:
Filter,band Pass-low Pass
Other Related Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC